 Technical specifications 
 | 
| 
 Ports 
 | 
 22 RJ-45 autosensing 10/100 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX) 
 | 
| 
 Duplex: half or full; 2 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T) 
 | 
| 
 Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only; 2 SFP autosensing 100/1000 ports (IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T) 
 | 
| 
 Duplex: 100BASE-TX: half or full; 1000BASE-T: full only; Supports a maximum of 22 autosensing 10/100 ports plus 2 autosensing 10/100/1000 ports plus 2 SFP ports 
 | 
| 
 Mounting 
 | 
 Mounts in an EIA-standard 19 in. telco rack (hardware included); horizontal surface, wall, and under-table mounting 
 | 
| 
 Memory and processor 
 | 
 128 MB RAM, packet buffer size: 512 KB, 8 MB flash 
 | 
| 
 Latency 
 | 
 100 Mb Latency: < 3.4 µs (64-byte packets) 
 | 
| 
 Throughput 
 | 
 up to 9.2 million pps 
 | 
| 
 Management features 
 | 
 Web browser 
 | 
| 
 Switching capacity 
 | 
 12.4 Gbps 
 | 
| 
 Connectivity and communications 
 | 
| 
 Denial of service protection 
 | 
 CPU DoS Protection 
 | 
| 
 General protocols 
 | 
 IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1W Rapid Spanning Tree Protocol; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3az Energy Efficient Ethernet; IEEE 802.3x Flow Control; RFC 1534 DHCP/BOOTP Interoperation; RFC 2030 Simple Network Time Protocol (SNTP) v4 
 | 
| 
 Network management 
 | 
 IEEE 802.1AB Link Layer Discovery Protocol (LLDP) 
 | 
| 
 Power and operating requirements 
 | 
| 
 Power consumption 
 | 
 22 W (maximum) 
 | 
| 
 Input voltage 
 | 
 100-127/200-240 VAC 
 | 
| 
 Input operating current 
 | 
 .4/.3 A 
 | 
| 
 Input frequency 
 | 
 50/60 Hz 
 | 
| 
 Safety 
 | 
 UL 60950-1; IEC 60950; EN 60950 
 | 
| 
 Electromagnetic compatibility 
 | 
 EN 55022 Class A; CISPR 22 Class A; VCCI V-3; FCC (CFR 47, Part 15) Subpart B Class A; VCCI V-4 
 | 
| 
 Operating temperature range 
 | 
 0 to 40°C 
 | 
| 
 Operating humidity range 
 | 
 15 to 95% @ 104°F (40°C) 
 | 
| 
 Operating altitude 
 | 
 up to 3 km 
 | 
| 
 Acoustic pressure emissions 
 | 
 Power: 0 dB, no fan 
 | 
| 
 Heat dissipation 
 | 
 204 BTU/hr (215.22 kJ/hr) 
 | 
| 
 Immunity standard 
 | 
 IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN 61000-3-2; EN 61000-3-3 
 | 
| 
 Dimensions and weight 
 | 
| 
 Minimum dimensions (W x D x H) 
 | 
 32.99 x 17.3 x 4.39 cm 
 | 
| 
 Weight 
 | 
 1 kg 
 |